LEAK ISOLATION WELL COMPLETIONS SYSTEMS
-
Long term isolation of water producing interval or leak below pump
-
For selective production of either interval situated above or below isolated interval
-
Completions system setting type hydraulic-mechanical. Upper packer hydraulic, lower packer- mechanical (axial setting type)
-
Released by standard overshot
STRADDLED LEAK ISOLATION COMPLETION WITH ESP
-
Isolation of the leak of casing where leak above of dynamic fluid level
-
Straddled completion allows complete isolation of leak
-
Gas bypass valve can be part of compeletion
-
Axial type of completion setting (no rotation)
-
Sealing of ESP cable without splice – by pulling of the cable through sealing elements of straddle (no cable armour damage)
-
Release of completion by pulling force
-
Bypass system for pressure equalization
ABOVE ESP LEAK ISOLATION COMPLETION
-
Isolation of the leak of casing where leak above of dynamic fluid level
-
Capillary pipe as a part of completion for chemicals pump to ESP zone
-
Axial type of completion setting (no rotation)
-
Sealing of ESP cable without splice – by pulling of the cable through sealing elements of straddle (no cable armour damage)
-
Release of completion by pulling force
WATER RE-INJECTION COMPLETION
-
Designed for pressure maintenance by re-injection from lower water bearing zone to upper pay zone
-
Axial type of completion setting (no rotation)
-
Sealing of ESP cable without splice – by pulling of the cable through sealing elements of straddle (no cable armour damage)
-
Release of completion by pulling force
SELECTIVE WATER INJECTION WELL COMPLETIONS SYSTEMS
-
Selective water injection in different reservoirs
-
Mono-tubing completions systems
-
Axial type of completion setting (no rotation)
-
Ability to perform logging through completion
-
Rate changes by replacement of choke valves in mandrels
SELECTIVE TREATMENT WELL COMPLETIONS SYSTEMS
-
Selective treatment of multi-layer formation
-
Axial type of completion setting (no rotation)
-
Multi-setting in one run of completion
-
Pressure differential up to 70MPa
-
Bigger ID for volume injection